I-Factory customized corrosion resistance pultrusion izimbuzi ipulazi imelela imbuzi i-fiberglass ugongolo lokweseka imilenze yembuzi
Ukusekela Imilenze Yembuzi Ephansi
Uhlu Lokuqukethwe
1. Iyini i-FRP goat farm slat floor stand beam?
2. Iyini inzuzo ye-FRP goat farm slat floor stand beam?
3. Izinto ezibonakalayo ze-FRP goat farm slat floor stand beam
4. Ukucaciswa kosayizi we-FRP goat farm slat floor stand beam
5. Isetshenziswani i-FRP goat farm slat floor stand beam?
1. Iyini i-FRP goat farm slat floor stand beam?
I-FRP goat farm slat floor stand beam inokusimama okungcono kunesitezi sensimbi, idumile epulazini lezimbuzi nezinye izindlu zemfuyo ezisekela izici zayo ezikhethekile, ezisetshenziswa kakhulu kudivayisi yokulima.
I-Marshine goat leg support ingakwazi ukumelana nemvelo egqwala kakhulu yendlu yezinkukhu, i-farrowing crate floor ngenkathi ithwele uhlelo olukhulu lokuthwala.
Njengokhuni, insimbi kanye ne-aluminium kwakuyizinye izinto ezicatshangelwa ekwakhiweni kwesitezi sepulazi lezimbuzi, nokho-ke, ayikho yalezo zinto ezinikeza amandla noma ukumelana nokugqwala kwaleyo khreyithi yepulazi lezimbuzi ezidingekayo ohlelweni lwazo lokubeka phansi.
2.Iyini inzuzo ye-FRP goat farm slat floor stand beam?
• Isisindo esilula, amandla aphezulu— kulula ukuyihambisa nokuyifaka ngamathuluzi ajwayelekile
• Imelana nokugqwala— ngeke ibole noma igqwale futhi imunca umswakama omncane
• Ubufakazi bokumelana namakhemikhali-okuncane kwe-asidi-alkali
• Ukumelana nokuswakama— akukho ukuncipha noma ukuvuvukala
• Ukumelana nomthelela— umata we-fiberglass usabalalisa umthwalo ukuvimbela ukulimala kwendawo
• Ukuphepha— ngeke kufake ugesi, futhi izindawo ezingasheleli ziyatholakala
• Ihlala isikhathi eside— izindleko zokuphila eziphansi kunezinto zokwakha zendabuko
• I-thermal conductivity ephansi— akubangeli ukushisa noma ukubanda kalula
• I-non-electrical conductivity, nempahla engeyona kazibuthe
• Isicishamlilo (sikhethiwe)
3.Izakhiwo ezibonakalayo ze-FRP goat farm slat floor stand beam
Imiphumela yokuhlola yezakhiwo zomzimba: | ||||
(Cha.) | Izinto zokuhlola | Iyunithi | Imiphumela yokuhlolwa | Izinga lokuhlola |
1 | Ukuminyana | g/cm3 | 1.85-1.9 | I-ASTM D792 |
2 | Ukumuncwa kwamanzi | % | 0.57 | I-ASTM D570 |
3 | Amandla e-Flexural | I-MPa | 302 | I-ASTM D790 |
4 | I-Flexural modulus | I-GPa | 18.6 | I-ASTM D790 |
5 | Amandla aqinile | I-MPa | 210 | I-ASTM D638 |
6 | I-tensile module | I-GPa | 22 | I-ASTM D638 |
7 | Isilinganiso se-flame retardant | V | V0/V1 | UL94 |
8 | I-voltage yokuhlukaniswa kwe-Dielectric | KV | 14.98 | I-ASTM D149-09 |
4.Ukucaciswa kosayizi we-FRP goat farm slat floor stand beam
Uhlobo | Imodeli | Usayizi | Isisindo/Kg/M |
I-FRP Beam engenalutho | H-80 | 80*30*5.5mm | 1.1kg/m |
| H-100 | 100*30*5.5mm | 1.35kg/m |
| H-120-1 | 120*30*5.5mm | 1.62kg/m |
| H-120-2 | 120*45* 5.5 mm | 2.36kg/m |
| H-135 | 135*30*5.5mm | 1.7kg/m |
| H-200 | 200*30*5.5mm | 2.7kg/m |
Unxantathu we-FRP Beam | S-100-01 | 100*30*5.5mm | 1.37kg/m |
| S-100-02 | 100*45*5.5mm | 1.4kg/m |
| S-120-01 | 120*30*5.5mm | 1.4kg/m |
| S-120-02 | 120*35*5.5mm | 1.4kg/m |
| S-120-03 | 120*45*5.5mm | 1.6kg/m |
| S-135-01 | 135*35*5.5mm | 1.5kg/m |
| S-135-02 | 135*45*5.5mm | 1.65kg/m |
| I-S-150 | 150*45*5.5mm | 1.79kg/m |
I-FRP Beam eqinile | T-60 | 60*25.4*5.5mm | 0.8kg/m |
| T-75 | 75*40*6.5mm | 1.2kg/m |
| T-100 | 100*25.4*5.5mm | 1.05kg/m |
| T-114 | 114*44.45*6.35mm | 1.33kg/m |
| I-T-120 | 120*25.4*5.5mm | 1.98kg/m |
| T-126 | 126*25.4*5.5mm | 1.3kg/m |
I-Trapezoid FRP Beam | I-Trapezoid-100 | 100*50*5.5mm | 1.8kg/m |
I-Trapezoid-120 | 120*50*5.5mm | 2.1kg/m |
5.Iyini ukusetshenziswa kwe-FRP goat farm slat floor stand beam?
1. Insimbi yethu yokusekela i-fiberglass ingumkhiqizo ongasindi kakhulu kodwa onamandla aphezulu.Kulula kakhulu ukuthutha ukuze kufakwe.
2. Kulula kakhulu ukufaka imishayo yokusekela ye-Marshine FRP ngamathuluzi ajwayelekile.
3. I-lamination emishayweni yokusekela unxantathu ye-FRP ivimbela ukugqwala futhi ifanele izindawo eziningi zesevisi.Imunca umswakama omncane kakhulu okwenza ingakwazi ukubola nokugqwala.
4. Le nsimbi yokusekela i-Marshine FRP evimbela umlilo imelana namakhemikhali enobufakazi obuncane be-asidi-alkali.
5. Uma kuqhathaniswa nezinto zokwakha zendabuko, i-fiberglass support beam ihlala isikhathi eside enciphisa izindleko
6. Ayiwuhambisi ugesi futhi indawo yayo engaphezulu ayisheleli okwenza iphephe kakhulu ukuyisebenzisa.Iphinde ibe ne-thermal conductivity ephansi ngakho ayibandi ukubanda noma ukushisa kalula.
7. Iyakwazi ukumelana nomswakama ukuze ingavuvukali noma inciphe.
8. Le nsimbi yokusekela ye-fiberglass imelana nomthelela ngoba impahla ye-fiberglass mat isabalalisa umthwalo ngokulinganayo ivimbele indawo emonakalweni.